Effektive opbevaringsteknikker og tabuer for ultrafiltreringsmembraner

Velkommen til at kontakte os WhatsApp
19. jun. 2024

Effektive opbevaringsteknikker og tabuer for ultrafiltreringsmembraner


1. Opbevaring af nye komponenter til ultrafiltreringsmembraner

Ensure that the original packaging of the ultrafiltration membranes components is intact and stored in a dark and cool place (temperature range of 0 to 40°C), avoiding direct sunlight and humid environment.

2. Storage of ultrafiltration membranes components after use

(1) I tilfælde af kortvarig nedlukning

If the shutdown is within 3 days, please stop the water supply and ensure that the membrane components are always filled with water and the temperature is between 0 and 40°C.

If the shutdown is between 4 and 7 dage, fill the ultrafiltration membranes components with the solution of concentration shown in Table 1. At least use qualified filtered water to prepare the solution and ensure that the temperature is between 0 and 40°C.
Tabel 1 Opbevaringsbetingelser for kortvarig nedlukning af membranmoduler (inden for 7 dage)
Maksimal opbevaringsperiode Kemisk agens Koncentration af opløsning
7 dage Natriumhypochlorit 20 mg/L (som Clz)
(2) I tilfælde af langvarig nedlukning

Udfør først kemisk rengøring med natriumhypochloritopløsning, og fyld derefter membranmodulet med kemikalier i den koncentration, der er vist i tabel 2. Brug mindst membranfiltreret vand og opbevar ultrafiltreringsmembranmodulet i henhold til retningslinjerne vist i tabel 2.

 
Table 2 Conditions required for long-term storage of membrane modules for more than 7 dage
Opbevaringsperiode Type lægemiddel, der skal opbevares Koncentration af lægemidler
7 dage Natriumbisulfit 1.000 mg/L


Seal the ultrafiltration membranes assembly with the aqueous solution shown in Table 1 or Table 2. If the ultrafiltration membranes assembly is removed from the device and stored offline, be sure to seal the membrane assembly, avoid direct sunlight during storage, and ensure that the temperature is between 0 and 40°C.

Bemærk: Efter kemisk rengøring med natriumhypochloritopløsning skal opløsningen i membranenheden skylles grundigt med rent vand, og derefter injiceres natriumbisulfitkonserveringsopløsning. Hvis den ikke skylles, vil blandingen af natriumhypochloritopløsning og natriumbisulfit producere giftig klorgas.

3. Udskift kemisk beskyttelsesopløsning

Hvis konserveringsopløsningen er natriumbisulfit, skal du regelmæssigt kontrollere, om pH-værdien af natriumbisulfitbeskyttelsesopløsningen er mellem 3 og 6. Normalt reagerer natriumbisulfit med ilt for at producere svovlsyre, og pH-værdien vil falde. Hvis pH-værdien er lavere end 3, skal konserveringsopløsningen udskiftes.